I need some help finding tutorials for WaterCAD when used as a plugin within AutoCAD. If you select the "Edit Control Sets for LCxxx" option, you can adjust the control sets for a selected control. This method allows you to create multiple composite conditions and actions using Edit composite tab in toolbar. Bentley WaterGEMS V8i Enterprise Edition was a first of a series of releases that revolutionized the way water planning was being done. 1. WaterGEMS CONNECT's powerful fire flow analysis capabilities can be used to determine if the system can meet the fire flow demands while maintaining various pressure constraints. Scenarios allow the user to calculate multiple "What If?" situations in a single project file. The Pattern Manager allows you to create the following types of patterns: The following management controls are located above the pattern list pane: The right half of the dialog consists of controls that allow you to define the settings for the pattern that is currently selected in the list of patterns on the left side of the dialog. Starting with the CONNECT Edition release of WaterGEMS and WaterCAD, you can now export the Flushing Area Summary Table for a given flushing run. Type required action elements; this is an example of composite control for cycling between pumps. Note:If you are using SewerCAD to model logical controls, the control priorities apply to individual pressure subnetworks. When first option is selected of duplicating full control, along with the control, condition and action of that control will also be duplicated, which you can see in the conditions and actions tab. The middle button, you have options to create a new simple or composite condition or action or find an existing condition or action. The new flushing module is easy to setup, easy to run (you can runa selected event or all events), and easy to generate printer ready reports. The flushing report's event elements table and operator's field report now provides context on valve/pipe status based on the prior event so the valve that was closed in the prior event, that should remain closed in the current event, doesn't have to be operated again and so the valves can return to the correct state when completing an event. Starting in the SELECTseries 6 release of WaterGEMS and WaterCAD, the Flushing tool has greatly been improved. At the bottom of the Controls dialog, click the middle button next to the Conditions and select Find Condition, or click the button on the right, which is the Find button. Below you will find methods to create new controls using new controls UI. JavaScript must be enabled in order to use this site. Also, the problem occurs in 10.4 in both the new controls UI as well as the classic. To create one from here, click the New button. A video has been created to showcase enhancements in new controls UI. There are also newly added actions for the pump element that will allow you to create a control to have a pump achieve a target pressure and pump target head, which will be useful for VSP pumps. The user creates new studies or areas by right-clicking on the study node in the left pane. If a hydrant or junction is selected, it is considered to be flowed. WaterGEMS. tank T-3 only, which can be seen in the status bar in below screenshot. Scroll down to understand how priorities work in controls. Gain insight and get answers to a wide range of topics related to Bentley products. Also, if you click on controls for a specific element through element properties, it will open new controls UI, with controls filtered for that element. For the THEN statement or action, use the Select button from the pulldown menu to select an element from the model or Find button to choose an element from the model. If the symbol is not present, then it's likely the control you created is not assigned to thecontrol set being utilized by the current Operational Alternative. (119 views) View Bentley water watergems demo PowerPoint (PPT) presentations online in SlideServe. You can also set up Nodes of Interest, which is an optional collection of nodes that you may deem important in the model. Whenone or moreconditions provided by the userare met during the model simulation, the action or actionsprovided by the user will be introduced in the model operation. WaterGEMS brings the concept of water modeling and GIS integration to the next level. I have searched around Youtube, Bentley CONNECT, Autodesk forums, most of the tutorials are how to use the Bentley standalone software (WaterGEMS or HAMMER or WaterCAD . An example of how this might work would be to toggle "Include nodes with pressure less than" and enter a value, such as 40 psi. Click the New button again to create another row. If priority does not appear to be working, check to make sure that all controls with conflicting actions are set as logical controls. Whereas the new controls editor user interface is more user friendly where you can see all the controls set for the model in a single table like flex table format, with option to filter table on required elements, control sets, on / off status etc. Use the second button to select the operational elements (hydrant, junction, valve). Toolbar It has options to create new controls, copy, past, edit etc. The steps will be similar to those in Method 2. Form which flushing operator can complete to describe results of flushing for feedback (optional). Join Bentley Communities to find how-to tips, Bentley
related to Bentley products. If none are available, click the ellipsis () button and choose from the available conditions or actions. Note that any demands from other elements such as junctions and customer meter elements will be accounted for during the flushing run. The second method you can open the Controls dialog is through the Properties. This will create new conditions related to the tank and new actions related to the pump. 3. Using stepwise instructions of Bentley WaterGEMS software lesson plans If your controls do not appear to be working as intended, see the following article for troubleshooting steps: Controls not being followed, Using Controls, Conditions, Actions and Control Sets in WaterGEMS and WaterCAD, New controls editor Vs Classic controls editor. Ideally, pipes in a run should be included in pipe set. Then click OK 4. Undo works for all types of element selections, including adding pipes in a path, adding single pipe, adding operational open element, adding operational close element and removing an element. The Highlight Previous button will highlight the previous event's elements. To identify whether an element has an active control, look for the following symbol next to the element. The user will see the Selection dialog where individual junctions or hydrants are selected. Once you have created controls, control sets, you can export them to a new file which can be saved as control file .ctl or as tab delimited excel file .txt. Status bar - It will display total number of elements listed in the table, if there is any filter applied, you can also choose to show controls in active control set only using status bar. Click here. The data in the Flushing Report will display correctly, but the Flushing Area Summary Table will show a different, incorrect value. If you need to upgrade to the latest version of the product, please refer link -Downloading OpenFlows products. To earn Bentley learning units, please view the video here: http://bit.ly/1eu7WQKPart 3 of 8: This video covers the basics of modeling and WaterGEMS. From the Operator column, choose AND or OR and then select another condition or action from the list. However, you will want to have controls for one element listed altogether, say controls for tank T-1 one after other to edit them as required. The program calculates a steady-state analysis for each node in the Fire Flow Alternative. Next,set the On Operator and Off Operator. "The pipe set for this area must contain at least one pipe. Note:To open a closed valve using controls, see this link: How to make a PRV, PSV, or FCV active after closing it with controls? A graph of the currently selected pattern is displayed in the lower right corner of the dialog. To activate the priority drop-down list, click the check box next to Priority. Elements must be active to affect flushing results. With CONNECT Edition,go to the Home or Analysis tab and select Alternative. Notice there is a new control that is undefined ("IF
Heise Pro Series Led Headlights, Turkish Towel Companies, Best Diaper Rash Spray, Eschborn-frankfurt Cycling 2022, Shopify Content Security Policy, Alameda Boat Slip Fees, Thule Roundtrip Transition Hard Case,